Meaning
Standardized compliance testing methods govern the measurement of radio frequency signals emitted by unlicensed wireless devices. The standard known as ansi c63.10-2013 specifies test setups, instrumentation, and frequency ranges for intentional radiators operating under federal communications commission rules. It establishes how an integration team must position an enclosure, route cables, and sweep frequencies during formal compliance testing.
The procedures apply from 9 kHz up to 234 GHz depending on the operating frequency of the internal transmitter. Beyond these operational boundaries, specialized millimeter-wave protocols take precedence over standard elevated ground plane configurations.
Measurement Setup
Physical placement of the device under test requires exact spacing relative to the receiving antenna and turntable center. Under ansi c63.10-2013, tabletop equipment sits on a non-conductive platform eighty centimeters above the reference ground plane for measurements below one gigahertz. Higher frequency sweeps require lifting the assembly to one point five meters to clear the antenna beamwidth.
Cable positioning introduces variations, so engineers must wiggle peripheral leads to maximize detected field strength.
Calibration Requirement
Verification of the test site relies on site voltage standing wave ratio measurements across the entire frequency range. Compliance with ansi c63.10-2013 mandates that receiving antennas maintain valid calibration factors traceable to national standards. Spectrum analyzers must use peak, quasi-peak, or average detectors as designated for each specific spectrum band.
Resolution bandwidth settings strictly dictate how narrow spurious signals are captured.
Integration Handover
Passing test logs form the final handover package required prior to commercial device distribution. Submission of reports executed under ansi c63.10-2013 verifies that custom antenna housings have not altered harmonic radiation profiles beyond statutory limits.