Meaning
Rate of change of velocity occurring during active moves of a coordinate measuring machine determines the positioning delay of the sensor. High dynamic acceleration allows faster inspections but introduces inertial forces that distort the physical frame. The measurement sequence must pause for these vibrations to settle before taking a valid data point.
Inertial Force
Physical deflection during sudden moves compromises the spatial coordinates of the probe head. Acceleration forces act against the stiffness of the machine structure, creating temporary bending. Machine designers balance the desire for speed against the accuracy penalties of flexing.
Component Fatigue
Wear on guide ways and drive belts increases when high acceleration cycles occur continuously. Guide bearings experience peak loads that exceed their static load ratings by substantial margins. These cyclic forces degrade the positioning repeatability of the drive system.
Mechanical Mitigation
Weight reduction using carbon fibre or hollow castings reduces the moving mass of the gantry. Lighter components experience lower inertial forces under the same drive inputs. This weight reduction shortens the measurement cycle without losing precision.
Finite element analysis directs the placement of internal ribs to maximize stiffness. Placing the drive axis close to the center of mass prevents rotational twisting during transitions.