Meaning
International standards define the physical layer specifications for high-speed controller area network communications. Devices compliant with iso 11898-2 operate with differential signal levels across a two-wire bus. This standard dictates the electrical characteristics of the transceivers and the medium.
Voltage Level
Transmitting a dominant bit requires the transceiver to create a minimum differential voltage of one point five volts between the bus lines. Under the rules of iso 11898-2, the receiver must detect any differential voltage above nine hundred millivolts as a dominant state. These specifications ensure that noise of several hundred millivolts does not cause false data reception.
Transceiver Parameter
Driver characteristics are closely regulated to ensure interoperability among different chip manufacturers. Compliance with iso 11898-2 requires that the transmitter can withstand short circuits to ground or to the supply voltage without being destroyed. Thermal shutdown circuits are integrated into the transceivers to prevent permanent damage if a bus fault persists.
Line Termination
Correct bus termination consists of two resistor networks placed at the extreme ends of the network. While iso 11898-2 specifies a nominal termination resistance of one hundred and twenty ohms, split termination techniques are often used to reduce electromagnetic emissions. The termination matches the cable impedance to prevent signal reflections that would otherwise corrupt the transmitted data.