Magnetic fields that escape the physical boundaries of a wire-wound component during operation can induce unwanted voltages in adjacent circuitry. This unintended magnetic radiation is known as inductor leakage flux, which is common in unshielded or poorly shielded power inductors. The presence of inductor leakage flux can interfere with nearby sensitive nodes, particularly in compact power converters where components are closely spaced.
This magnetic coupling is especially severe at high switching frequencies.
Coupling Mechanism
Unshielded power inductors radiate magnetic fields that couple directly into sensitive high-impedance nodes or trace loops. This coupling occurs when inductor leakage flux induces a noise voltage on the sensitive trace, which is then amplified by downstream circuits. Radio frequency receivers are highly susceptible to this noise, which degrades their sensitivity.
Component Selection
Mitigation of this magnetic coupling begins with the selection of shielded inductors or toroidal cores. A shielded inductor uses a magnetic sleeve to contain the inductor leakage flux, preventing it from radiating outward. While these components are slightly more expensive, they are essential for passing electromagnetic compatibility tests in dense designs.
Layout Mitigation
Orientation of the component on the circuit board also influences the coupling of magnetic fields. Aligning the component so that the direction of the inductor leakage flux does not cross sensitive traces reduces the induced noise. Adequate physical separation between the inductor and sensitive radio modules further minimizes this interference.