Meaning
Quantitative analysis of ionic contamination on printed board surfaces utilizes resistivity of solvent extract measurements. Technicians use ipc tm 650 method 2 3 28 to detect flux residues and plating salts that could lead to dendrite growth. The process involves submerging the board in a solution of isopropanol and deionized water.
Testing Protocol
The conductivity of the solution increases as ionic species dissolve from the surface of the assembly. Following ipc tm 650 method 2 3 28 allows the operator to calculate the equivalent amount of sodium chloride contamination per square centimeter. This baseline informs the adequacy of the final aqueous cleaning stage in the production line.
Measurements are taken at specific intervals to ensure the extraction process has reached a state of equilibrium.
Pass Criterion
Industrial standards set the limit for cleanliness at 1.56 micrograms of sodium chloride equivalent per square inch. Results from ipc tm 650 method 2 3 28 provide a go or no-go signal for the conformal coating process. High contamination levels prevent the coating from adhering correctly to the substrate.
Regular calibration of the ionograph equipment maintains the accuracy of these readings over time.
Methodology Limit
Modern assemblies with low-profile components like land grid arrays make the extraction of ions from under the parts more difficult. While ipc tm 650 method 2 3 28 is a standard industry tool, it may not detect all hidden residues in high-density interconnects.