Meaning
Graphic representations of voltage over time for high energy density primary cells show how energy is delivered under varying load conditions. These lithium thionyl chloride discharge curves are essential for predicting the lifespan of a remote sensor in the field. They show a characteristic flat voltage plateau followed by a sharp drop at the end of the battery life.
Engineers use this data to set the low battery warning thresholds in the system firmware.
Voltage Plateau
Primary cells using this chemistry maintain a very stable output near 3.6 volts for the majority of their service life. The lithium thionyl chloride discharge curves demonstrate that the voltage does not drop significantly as the capacity is consumed. This stability is ideal for powering sensitive analog circuits without the need for complex regulators.
It also makes it difficult to estimate the remaining energy based on voltage alone. Most systems must use a coulomb counter to track the actual energy used by the device. The flat nature of the curve is a result of the stable electrochemical reaction within the cell.
Passivation Effect
Storage of the battery can lead to the formation of a high resistance layer on the lithium anode. The lithium thionyl chloride discharge curves for a cell that has been idle for months will show an initial voltage dip when a load is first applied. This dip can trigger a premature system reset if the firmware is not designed to wait for the voltage to recover.
Capacity Delivery
Total energy extracted from the cell depends on the magnitude of the discharge current. High pulse loads move the lithium thionyl chloride discharge curves downward and reduce the total usable capacity. This reduction is caused by internal resistance and the limits of ion diffusion through the electrolyte.