Meaning
Quantitative analysis of the salts and residues remaining on an electronic assembly determines the risk of electrochemical migration and corrosion. Modern ionic contamination testing typically employs the resistivity of solvent extract method to detect invisible ions like chlorides or flux activators. These residues can become conductive in the presence of moisture, leading to short circuits.
Extraction Process
The board is submerged in a mixture of isopropyl alcohol and deionized water to dissolve any surface contaminants. During ionic contamination testing, the machine continuously monitors the conductivity of the fluid as it circulates over the sample. The final reading is expressed in micrograms of sodium chloride equivalent per square centimeter.
Limit Specification
Industrial standards like IPC-6012 define the maximum allowable levels of ions based on the end-use environment of the product. While older standards allowed for higher levels of residue, modern ionic contamination testing often requires results below 1.56 micrograms per square centimeter for high-reliability applications. Boards failing this test must go through an additional cleaning cycle before they can be coated or shipped.
Reliability Impact
Conductive ions left under small components can grow metallic whiskers called dendrites. If ionic contamination testing is neglected, these growths can eventually bridge the gap between traces and cause intermittent failures. This risk is especially high for devices operating in humid or tropical climates where moisture is constantly present.