Meaning
Battery-powered devices experience a sudden drop in supply voltage when transitioning from deep sleep to active transmission. This transient voltage delay is caused by the high resistance of the passivation layer on lithium thionyl chloride anodes. It limits the immediate current delivery capability of the battery and can cause premature low-voltage shutdown.
This phenomenon must be modeled during the battery selection phase to ensure long-term field reliability.
Passivation Layer
A protective film of lithium chloride forms on the anode during long periods of inactive storage. When the load current rises, transient voltage delay occurs as this film resists the flow of ions. This film must be broken down by the chemical action of the discharge current itself.
Mitigation Technique
Hardware designs include parallel capacitors or lithium-ion capacitors to supply the initial current spike. By bypassing the battery during the first few milliseconds, transient voltage delay is kept above the reset threshold. This bypass allows the device to operate safely even after years of continuous sleep.
Pre-discharge Routine
Firmware can be programmed to draw a small, controlled current before activating the main RF transceiver. This pre-discharge routine slowly breaks down the passivation layer without triggering a low-voltage reset. This software technique represents a low-cost alternative to adding large and expensive capacitors to the circuit board.