Meaning
Contact smart cards and subscriber identity modules transmit a standardized byte sequence immediately following the release of an electrical reset signal to declare communication capabilities to an interface device. Defined primarily by ISO/IEC 7816-3, the answer to reset conveys initial parameters including supported transmission protocols, clock rate conversion factors, programming voltage requirements and historical operating data. The transmission stops once the indicated historical bytes and optional check character reach the terminal reader.
Processing aborts if the sequence violates timing windows or checksum rules defined for the physical interface.
Protocol Declaration
Transmission begins with an initial character establishing byte convention, followed by format bytes that define subsequent interface bytes. The answer to reset signals whether the card operates under character-level asynchronous protocol T=0 or block-level protocol T=1 through specific interface indicators. Baud rate adjustments rely on the declared parameters Fi and Di, which modify the elementary time unit relative to the supplied clock frequency.
Default configurations apply when optional parameters remain unpopulated by the card operating system. Timing compliance mandates that the leading edge of the start bit of the initial byte occurs between 400 and 40,000 clock cycles after the reset line transition.
Card Qualification
Acceptance testing during incoming inspection uses hardware bus analyzers to verify that electrical parameters match modem interface requirements. Variations in the answer to reset can cause modem firmware to misconfigure internal pull-up strengths, parity calculation or serial clock divisors. Test benches log electrical rise times and edge intervals across temperature extremes to confirm that the sequence executes before host timeout limits expire.
Conformance reports formally document the byte array alongside electrical oscillograms as proof of physical layer compliance before potting or mechanical assembly.
Cold Reset
Power application precedes an initial cold sequence where the modem supplies ground, asserts supply voltage, activates clocking lines, and releases the reset pin. If the card produces a malformed answer to reset or remains silent during the mandatory interval, the host controller triggers a warm reset sequence without cycling the core voltage lines. Repeated negotiation failure initiates an automatic power-down sequence to prevent bus contention or latch-up events on shared interface lines.
Verification gates down the production line check these state transitions to guard against field failures where subscriber identity modules become permanently unresponsive during supply dips.