Meaning
Printed circuit board test structures designed for vector network analyzer calibration integrate an unpopulated transmission line twice the length of the launcher transition. A 2x thru coupon provides the physical measurement data necessary to characterize and mathematically remove trace transitions and launch connectors from high-speed S-parameter measurements. Calibration algorithms split the measured S-parameters of the coupon into two symmetrical halves representing the left and right test fixtures.
This de-embedding process terminates at the designated reference plane of the device under test.
Launch De-embedding
Signal integrity characterization relies on isolating component performance from board parasitics. High-frequency vector network analyzer measurements capture total insertion loss and return loss, which bundle the trace launches together with the device under test. By applying matrix mathematics to the 2x thru coupon measurement, automated fixture removal software calculates half-thru S-parameters.
The mathematical operation isolates the exact S-parameters of the launch structure. Subtracting these fixture matrices from the total raw measurement isolates the standalone performance of the integrated device. This method eliminates the requirement for physical calibration standards manufactured on identical substrate materials.
Structural Symmetry
Symmetrical layouts are essential for accurate fixture extraction. The 2x thru coupon must feature identical trace geometry, substrate stackup, layer transitions, and connector footprints on both ends of the central reference line. Discrepancies in trace width or dielectric thickness introduce phase errors during the mathematical splitting operation.
Small physical variations skew the calculated reference planes and corrupt high-frequency S-parameters beyond several gigahertz.
Impedance Boundary
Measurement accuracy degrades when trace impedance strays from target system values. Broad tolerances in board fabrication alter the characteristic impedance of the 2x thru coupon relative to the target product traces. High-frequency reflections occur at mismatched boundaries, rendering extracted fixture parameters invalid for de-embedding adjacent channels.